YOKOGAWA uR10000/20000 Recorder Åë½Åµå¶óÀ̹ö´Â ÀϺ» Yokogawa Electric CorporationÀÇ uR10000/uR20000 Recorder Àåºñ¿Í Åë½ÅÀ» À§ÇÑ µå¶óÀ̹öÀÌ´Ù.
Âü°í) ÇöÀç YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹ö´Â FD Àб⠸í·É¸¸ Áö¿øÇÑ´Ù. (ÃßÈÄ Ãß°¡Áö¿ø ¿¹Á¤)
<±×¸² 1>Àº YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹ö¸¦ »ç¿ëÇÏ¿© Åë½ÅÆÄÀÏÀ» ÆíÁýÇÑ ¿¹ÀÌ´Ù.
![]() |
<±×¸² 1> YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ Åë½ÅÆÄÀÏ ÆíÁý ¿¹ |
<±×¸² 1>¿¡¼ DEVICE´Â ¿¬°áÇü½Ä(TCP/IP), Recorder ÀÇ IP ¹øÁö(100.100.100.44), ¼ºñ½º Æ÷Æ®¹øÈ£(34260) ¼øÀ¸·Î Àåºñ¿¡ ¼³Á¤µÈ °ªÀ» ÀÔ·ÂÇÑ´Ù.
¶ÇÇÑ '¿É¼Ç'ºÎ¿¡´Â Login »ç¿ëÀÚ¸í(±âº» = user), ¾ÏÈ£(±âº» = 1)¸¦ ÄÞ¸¶( , )·Î ±¸ºÐÇÏ¿© ÀÔ·ÂÇÑ´Ù.
YOKOGAWA uR10000/20000 Recorder Åë½Åµå¶óÀ̹öÀÇ Àбâ ÀÛ¼º Çü½Ä
YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ Àбâ Çü½ÄÀº ´ÙÀ½°ú °°Àº ÀÎÀÚ ¼øÀ¸·Î »ç¿ëÇÑ´Ù.
1) STATION – »ç¿ë¾ÈÇÔ.
2) Àб⠸í·É¾î – FD Àб⠸í·É¾î¸¦ ÀÔ·Â.(<Ç¥ 1> ÂüÁ¶)
3) ÀÐÀ» ÁÖ¼Ò – Àб⠽ÃÀÛÇÒ Ã¤³Î¹øÈ£¸¦ ÀÔ·Â. (uR10000 = 1 ~ 6, uR20000 = 1 ~ 24)
4) ¸Þ¸ð¸® ÀúÀå À§Ä¡ – Àоî¿Â »óŰªÀ» ÀúÀåÇÒ Åë½Å¸Þ¸ð¸® ½ÃÀÛ¹øÁö¸¦ ÀÔ·Â.
5) Àд ũ±â – Çѹø¿¡ Àоî¿Ã ä³ÎÀÇ °³¼ö. uR10000 = 1 ~ 6, uR20000 = 1 ~ 24.
Àб⠼³Á¤ ¿¹)
READ, 0, FD, 1, 0, 5,
<Ç¥ 1>Àº YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ FD Àб⠸í·É¿¡ ´ëÇÑ ÀÐÀº °ª ÀúÀåÀ§Ä¡¿Í ³»¿ëÀÌ´Ù.
<Ç¥ 2>´Â flag °ªÀÇ ºñÆ®º° ÀǹÌÀ̰í <Ç¥ 3>Àº °æº¸ °ª¿¡ µû¸¥ °æº¸ ³»¿ëÀ̸ç <Ç¥ 4>´Â Special Data Value °ªº° µ¥ÀÌÅÍ ÀǹÌÀÌ´Ù.
Àб⠸í·É¾î | ³»¿ë | ÀÐÀº °ª ÀúÀå ³»¿ë |
FD | Measured/ Computed Data Àбâ |
ÀúÀå À§Ä¡ + 0 ~ 6 : ÃøÁ¤ ³â, ¿ù, ÀÏ, ½Ã, ºÐ, ÃÊ, mSec ÀúÀå À§Ä¡ + 7 : reserved ÀúÀå À§Ä¡ + 8 : flag(<Ç¥ 2> ÂüÁ¶) ------------------------------------------------- ÀúÀå À§Ä¡ + 9 : Measured( 00h )/Computed( 80h ) »óÅ °ª ÀúÀå À§Ä¡ + 10 : ä³Î ¹øÈ£(1 ~ 6 or 1 ~ 24) ÀúÀå À§Ä¡ + 11 ~ 14 : Alarm 1 ~ 4 »óÅ °ª(<Ç¥ 3> ÂüÁ¶) ÀúÀå À§Ä¡ + 15 : Special Data Value ¿©ºÎ (Ç¥ 4> ÂüÁ¶) ÀúÀå À§Ä¡ + 16 : Measured/Computed Data ------------------------------------------------- ÀúÀå À§Ä¡ + 17 ~ 24 : µÎ¹ø ° ä³Î µ¥ÀÌÅÍÀÇ ÀÐÀº °ª ...., |
<Ç¥ 1> YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ FD Àб⠸í·É¿¡ ´ëÇÑ ÀÐÀº °ª ÀúÀåÀ§Ä¡¿Í ³»¿ë |
Bit | ³»¿ë |
0 | Indicates that the internal process took too much time (computation, for example) and that FIFO dropout occurred. |
1 | Indicates that the FIFO acquiring interval was changed during measurement. |
2 | Indicates that the decimal position or unit information was changed during measurement. |
3 ~ | Don't care. |
<Ç¥ 2> flag °ªÀÇ ºñÆ®º° ÀÇ¹Ì |
°ª | °æº¸ ³»¿ë |
0 | 0 = no alarm |
1 ~ 8 | Alarm ¹ß»ý, 1 = H(high limit alarm), 2 = L(low limit alarm), 3 = h(difference high-limit alarm), 4 = l(high limit on rate-of-change alarm), 5 = R(high limit on rate-of-change alarm), 6 = r(low limit on rate-of-change alarm), 7 = T(delay high limit alarm), 8 = t(delay low limit alarm). |
<Ç¥ 3> °æº¸ °ª¿¡ µû¸¥ °æº¸ ³»¿ë |
°ª | ÀÇ¹Ì |
00h | Á¤»ó µ¥ÀÌÅÍ |
01h | + Over |
02h | – Over |
04h | Skip |
08h | Burnout (when ¡°up¡± is set) |
10h(16) | Burnout (when ¡°down¡± is set) |
20h(32) | Error |
40h(64) | Differential input |
80h(128) | Undefined |
<Ç¥ 4> Special Data Value °ªº° µ¥ÀÌÅÍ ÀÇ¹Ì |
YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ ÀÐÀº °ªÀº WORD/DWORD/FLOAT/DOUBLE ¸Þ¸ð¸®¿¡ µ¿ÀÏÇÑ °ª(ÀúÀåÇü½Ä¸¸ ´Ù¸§)ÀÌ ÀúÀåÇÑ´Ù.
<±×¸² 1> ÇÁ·ÎÅäÄÝ ¿É¼ÇºÎÀÇ
¾ÆÀÌÄÜÀ» Ŭ¸¯Çϸé <±×¸² 2>ÀÇ ´ëÈ»óÀÚ°¡ ³ªÅ¸³ª´Âµ¥ ¿©±â¼µµ Àбâ Çü½ÄÀ» ÀÛ¼ºÇÒ ¼ö ÀÖ´Ù.
![]() |
<±×¸² 2> YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ ¿É¼Ç ´ëÈ»óÀÚÀÇ ¿¹ |
<±×¸² 2>ÀÇ
,
,
¹öÅϰú ¸®½ºÆ® ¹Ú½º¸¦ ÀÌ¿ëÇÏ¿© Àбâ Çü½ÄÀ» ÀÛ¼ºÇÑ´Ù.
<±×¸² 2>ÀÇ 'ID' ¿µ¿ª°ú 'Password' ¿µ¿ª¿¡¼µµ Login »ç¿ëÀÚ¸í°ú ¾ÏÈ£¸¦ ¼³Á¤ÇÒ ¼ö ÀÖ´Ù.
![]() |
<±×¸² 3> YOKOGAWA uR10000/20000 Recorder µå¶óÀ̹öÀÇ Åë½Å Àб⠼³Á¤ Ãß°¡/ÆíÁý ´ëÈ»óÀÚÀÇ ¿¹ |
<±×¸² 3>Àº <±×¸² 2>ÀÇ ´ëÈ»óÀÚ¿¡¼ Àб⠽ºÄÉÁìÀ» Ãß°¡ ¶Ç´Â ÆíÁýÇÒ ¶§ ³ªÅ¸³ª´Â ´ëÈ»óÀÚÀÌ´Ù.
YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ ¾²±â ¼³Á¤Àº Áö¿øÇÏÁö ¾Ê´Â´Ù. (ÃßÈÄ Áö¿ø¿¹Á¤)
<±×¸² 4>´Â YOKOGAWA uR10000 Recorder ÀåºñÀÇ ¸ð½ÀÀÌ´Ù.
![]() |
<±×¸² 4> YOKOGAWA uR10000 Recorder ÀåºñÀÇ ¸ð½À |