YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹ö

 

YOKOGAWA uR10000/20000 Recorder Åë½Åµå¶óÀ̹ö´Â ÀϺ» Yokogawa Electric CorporationÀÇ uR10000/uR20000 Recorder Àåºñ¿Í Åë½ÅÀ» À§ÇÑ µå¶óÀ̹öÀÌ´Ù.

 

Âü°í) ÇöÀç YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹ö´Â FD Àб⠸í·É¸¸ Áö¿øÇÑ´Ù. (ÃßÈÄ Ãß°¡Áö¿ø ¿¹Á¤)

 

1. Àб⠼³Á¤

 

<±×¸² 1>Àº YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹ö¸¦ »ç¿ëÇÏ¿© Åë½ÅÆÄÀÏÀ» ÆíÁýÇÑ ¿¹ÀÌ´Ù. 

<±×¸² 1> YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ Åë½ÅÆÄÀÏ ÆíÁý ¿¹

 

<±×¸² 1>¿¡¼­ DEVICE´Â ¿¬°áÇü½Ä(TCP/IP), Recorder ÀÇ IP ¹øÁö(100.100.100.44), ¼­ºñ½º Æ÷Æ®¹øÈ£(34260) ¼øÀ¸·Î Àåºñ¿¡ ¼³Á¤µÈ °ªÀ» ÀÔ·ÂÇÑ´Ù.

¶ÇÇÑ '¿É¼Ç'ºÎ¿¡´Â Login »ç¿ëÀÚ¸í(±âº» = user), ¾ÏÈ£(±âº» = 1)¸¦ ÄÞ¸¶( , )·Î ±¸ºÐÇÏ¿© ÀÔ·ÂÇÑ´Ù.

 

 

YOKOGAWA uR10000/20000 Recorder Åë½Åµå¶óÀ̹öÀÇ Àбâ ÀÛ¼º Çü½Ä

YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ Àбâ Çü½ÄÀº ´ÙÀ½°ú °°Àº ÀÎÀÚ ¼øÀ¸·Î »ç¿ëÇÑ´Ù.

1) STATION – »ç¿ë¾ÈÇÔ.

2) Àб⠸í·É¾î – FD Àб⠸í·É¾î¸¦ ÀÔ·Â.(<Ç¥ 1> ÂüÁ¶)

3) ÀÐÀ» ÁÖ¼Ò – Àб⠽ÃÀÛÇÒ Ã¤³Î¹øÈ£¸¦ ÀÔ·Â. (uR10000 = 1 ~ 6, uR20000 = 1 ~ 24)

4) ¸Þ¸ð¸® ÀúÀå À§Ä¡ – Àоî¿Â »óŰªÀ» ÀúÀåÇÒ Åë½Å¸Þ¸ð¸® ½ÃÀÛ¹øÁö¸¦ ÀÔ·Â.

5) Àд ũ±â – Çѹø¿¡ Àоî¿Ã ä³ÎÀÇ °³¼ö.  uR10000 = 1 ~ 6, uR20000 = 1 ~ 24.

 

Àб⠼³Á¤ ¿¹)

READ, 0, FD, 1, 0, 5,
 

<Ç¥ 1>Àº YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ FD Àб⠸í·É¿¡ ´ëÇÑ ÀÐÀº °ª ÀúÀåÀ§Ä¡¿Í ³»¿ëÀÌ´Ù.

<Ç¥ 2>´Â flag °ªÀÇ ºñÆ®º° ÀǹÌÀ̰í <Ç¥ 3>Àº  °æº¸ °ª¿¡ µû¸¥ °æº¸ ³»¿ëÀ̸ç <Ç¥ 4>´Â Special Data Value °ªº° µ¥ÀÌÅÍ ÀǹÌÀÌ´Ù.

Àб⠸í·É¾î ³»¿ë ÀÐÀº °ª ÀúÀå ³»¿ë
FD Measured/
Computed Data
Àбâ
ÀúÀå À§Ä¡ + 0 ~ 6 :  ÃøÁ¤ ³â, ¿ù, ÀÏ, ½Ã, ºÐ, ÃÊ, mSec
ÀúÀå À§Ä¡ + 7 :  reserved
ÀúÀå À§Ä¡ + 8 :  flag(<Ç¥ 2> ÂüÁ¶)
-------------------------------------------------
ÀúÀå À§Ä¡ + 9 :  Measured( 00h )/Computed( 80h ) »óÅ °ª
ÀúÀå À§Ä¡ + 10 :  ä³Î ¹øÈ£(1 ~ 6 or 1 ~ 24)
ÀúÀå À§Ä¡ + 11 ~ 14 :  Alarm 1 ~ 4 »óÅ °ª(<Ç¥ 3> ÂüÁ¶)
ÀúÀå À§Ä¡ + 15 :  Special Data Value ¿©ºÎ (Ç¥ 4> ÂüÁ¶)
ÀúÀå À§Ä¡ + 16 :  Measured/Computed Data
-------------------------------------------------
ÀúÀå À§Ä¡ + 17 ~ 24 :  µÎ¹ø ° ä³Î µ¥ÀÌÅÍÀÇ ÀÐÀº °ª
....,
<Ç¥ 1> YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ FD Àб⠸í·É¿¡ ´ëÇÑ ÀÐÀº °ª ÀúÀåÀ§Ä¡¿Í ³»¿ë
Bit ³»¿ë
0 Indicates that the internal process took too much time (computation, for example) and that FIFO dropout occurred.
1 Indicates that the FIFO acquiring interval was changed during measurement.
2 Indicates that the decimal position or unit information was changed during measurement.
3 ~ Don't care.
<Ç¥ 2> flag °ªÀÇ ºñÆ®º° ÀǹÌ
°ª °æº¸ ³»¿ë
0 0 = no alarm
1 ~ 8 Alarm ¹ß»ý, 
1 = H(high limit alarm), 2 = L(low limit alarm), 3 = h(difference high-limit alarm),
4 = l(high limit on rate-of-change alarm), 5 = R(high limit on rate-of-change alarm),
6 = r(low limit on rate-of-change alarm), 7 = T(delay high limit alarm), 8 = t(delay low limit alarm).
<Ç¥ 3> °æº¸ °ª¿¡ µû¸¥ °æº¸ ³»¿ë
°ª ÀǹÌ
00h Á¤»ó µ¥ÀÌÅÍ
01h + Over
02h – Over
04h Skip
08h Burnout (when ¡°up¡± is set)
10h(16) Burnout (when ¡°down¡± is set)
20h(32) Error
40h(64)  Differential input
80h(128) Undefined
<Ç¥ 4> Special Data Value °ªº° µ¥ÀÌÅÍ ÀǹÌ

 

YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ ÀÐÀº °ªÀº WORD/DWORD/FLOAT/DOUBLE ¸Þ¸ð¸®¿¡ µ¿ÀÏÇÑ °ª(ÀúÀåÇü½Ä¸¸ ´Ù¸§)ÀÌ ÀúÀåÇÑ´Ù.

<±×¸² 1> ÇÁ·ÎÅäÄÝ ¿É¼ÇºÎÀÇ  ¾ÆÀÌÄÜÀ» Ŭ¸¯Çϸé <±×¸² 2>ÀÇ ´ëÈ­»óÀÚ°¡ ³ªÅ¸³ª´Âµ¥ ¿©±â¼­µµ Àбâ Çü½ÄÀ» ÀÛ¼ºÇÒ ¼ö ÀÖ´Ù.

<±×¸² 2> YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ ¿É¼Ç ´ëÈ­»óÀÚÀÇ ¿¹

 

<±×¸² 2>ÀÇ , ,  ¹öÅϰú ¸®½ºÆ® ¹Ú½º¸¦ ÀÌ¿ëÇÏ¿© Àбâ Çü½ÄÀ» ÀÛ¼ºÇÑ´Ù.

<±×¸² 2>ÀÇ 'ID' ¿µ¿ª°ú 'Password' ¿µ¿ª¿¡¼­µµ Login »ç¿ëÀÚ¸í°ú ¾ÏÈ£¸¦ ¼³Á¤ÇÒ ¼ö ÀÖ´Ù.

<±×¸² 3> YOKOGAWA uR10000/20000 Recorder µå¶óÀ̹öÀÇ Åë½Å Àб⠼³Á¤ Ãß°¡/ÆíÁý ´ëÈ­»óÀÚÀÇ ¿¹

 

<±×¸² 3>Àº <±×¸² 2>ÀÇ ´ëÈ­»óÀÚ¿¡¼­ Àб⠽ºÄÉÁìÀ» Ãß°¡ ¶Ç´Â ÆíÁýÇÒ ¶§ ³ªÅ¸³ª´Â ´ëÈ­»óÀÚÀÌ´Ù.

 

 

2. ¾²±â ¼³Á¤

YOKOGAWA uR10000/20000 Recorder Åë½Å µå¶óÀ̹öÀÇ ¾²±â ¼³Á¤Àº Áö¿øÇÏÁö ¾Ê´Â´Ù. (ÃßÈÄ Áö¿ø¿¹Á¤)

 

 

3. uR10000 ÀåºñÀÇ ¸ð½À

<±×¸² 4>´Â YOKOGAWA uR10000 Recorder ÀåºñÀÇ ¸ð½ÀÀÌ´Ù.

<±×¸² 4> YOKOGAWA uR10000 Recorder ÀåºñÀÇ ¸ð½À